Two Stage Reverse Osmosis Pure Water Equipment

1. Output water conductivity: ≤ 5μS/cm.

2. Scientific design, water recovery rate ≥ 65%.

3. Compact construction, reasonable pipe laying.

4. User friendly -- full-automatic control with PLC & touch screen.

5. Online conductivity monitoring for output water.

6. System stops in case of water shortage or tank full.

7. Auto flushing for RO membrane to reduce the RO membrane pollution.

8. USA DOW reverse osmosis membrane, with a long service life for 3-5 years.

9. CNP SUS pump, durable and low running noise.

10. Self-developed pretreatment system, greatly protect the RO membrane.

What is Reverse Osmosis?

RO is a kind of membrane separation technology developed in the 1960s. It is working on the principle that water pass through the RO membrane whose bore diameter is 1/10000μm (1/60000 size of Escherichia coli, 1/3000 size of virus) from higher concentrated side to the lower one by pressurize. So that the industrial pollutants and impurities such as metal ions, bacteria, viruses separated from the input water. 




Two Stage RO Equipment Introduction

A complete 2 stage RO pure water equipment consists of pretreatment system, stage-1 RO system, PH regulating system, middle pure water storage system (optional for large equipment), stage-2 RO system, water storage tanks, and auto backwash system. The stage-2 RO system is a deeper purification system for the stage-1. This kind of system is suitable for poor quality raw water or particularly use for higher water quality requirement.


Pretreatment system is normally composed of quartz sand filter, activated carbon filter, soften filter and precision filter. The mainly working purpose is to protect the following RO membrane by separating large particle pollutants such as sediments, colloid, suspended solids, pesticides, especially residual chlorne and organism from the raw water. And softening equipment is needed to protect the following RO membrane from scaling and block if the raw water is of high Ca2+ or Mg2+ ion content.

RO host is the key part of the whole system as it determines the output water quality. The RO host mainly consists of booster pumps, membrane shell, RO membrane, control circuit and so on. The salinity filtering ability of a single RO membrane can be above 99%. The conductivity of stage-1 RO water will be within 10μs/cm(25℃), and stage-2 RO water will be of less than 5μs/cm(25℃) if with reasonable design. So the design reasonability will directly determine the cost-effective and operating convenience of the system. And power-saving, operating pressure, desalination rate, saltness of output water and receovery rate should be taken into consideration during design process.


And PH regulating system is need for a two stage RO system. As the RO membrane could reduce little CO2, the output water of RO system is acidic. We adopted PH regulating system to control the acidic first stage RO water to weakly basic, so that the second stage RO water will be neutral. PH regulating system is composed of chemical tank, dosing pump, relative valves and pipes. 


The pre-treated water couldn’t come into the RO system unless the SDI is less than 4. And after RO processing, pure water(desalted water) will come into the storage tank, stage-1 concentrate water will be discharged and stage-2 concentrate water will be recycled to raw water system so as to increase the receovery rate.




Processing Technology



Solution Ways

Output water quality

Processing technology

Material

Conductivity ≤ 10us/cm

1-stage RO system

FRP/SUS + PVC/SUS

Conductivity ≤ 5us/cm

2-stage RO system

FRP/SUS + PVC/SUS

Conductivity ≤ 2us/cm

2-stage RO system

Full SUS

Resistivity: ≥ 15MΩ·CM

2-stage RO system + EDI

FRP/SUS + PVC/SUS

Resistivity: ≥ 18.25MΩ·CM

2-stage RO system + EDI + Polishing

FRP/SUS + PVC/SUS




Application Field

Manufacturing Industry

Automobile, Glasses, Steel Material, Textile, Papermaking etc.

Electrical Power Industry

Boiler, Thermal power, Generation, System cooling, Water recycling etc.

Electroplating Industry

Film Coating, Lighting, Cooling, metal plating etc.

Opto-electronics Industry

Photovoltaic, Opto-electronics, New energy, LED lights etc.

Electronics Industry

Electrical appliance, chip, circuit board, singlechip etc.

Energy Industry

Semi-conductor, Silicon material, Polysilicon, Metal extraction etc.

Chemical industry

Petrochemical, Reaction cooling, Solution prepare, Material producing and processing etc.

Fine Chemicals Industry

Wet wipes, Face mask, Skincare, Shampoo, Hair dye, Tooth paste, Hand sanitizer, Detergent, cosmetics etc.

Pharmaceuticals Industry

Medical device producing, bioengineering, bio-medicine, oral liquid pharmacy, medical material extraction etc.

Operation Parameters

Capacity

Customized

Raw Water

Tap water or groundwater (Conductivity ≤ 400μS/cm)

Output Water

conductivity ≤ 5μS/cm

Recovery

65% - 75%

Automation

Auto operation, back washing at regular time

Back Washing Frequency

Vary between 1 to 3 days according to the input water quality

Chemical Washing Frequency

According to the membrane material and polluted situation

Characteristics

Compact construction, stable operation and reliable output water

6/MN, Block 9C,Baoneng Technology Park,Qingxiang Road, Longhua New District, Shenzhen, 518109, CHINA
  • P: +86-18818589386
  • F: +86-755-84158066
  • Email: osmarket@hshbzg.com